CRITICAL POWER  ·  SKU: TV-UPS-ODC110K

Online Double-Conversion UPS — 1kVA to 10kVA Series

★★★★★ 4.9 / 5  (182 installations)

Zero transfer time continuous pure sine wave power for enterprise servers, medical diagnostics, and sensitive lab equipment. Delivers complete isolation from grid fluctuations, frequency variation, and harmonic noise.

Best Seller
Terravolt DC EV Charger 30-180kW unit
Starting at Request Quote
In stock — ships in 1–2 weeks
✔ 3-Year Extended Warranty
✔ 24/7 Technical Support & Sizing Service
✔ CE / UL / IEC 62040 Certified
  • ⚡ Capacity range: 1kVA – 10kVA
  • ⏱️ Transfer time: 0 ms (Zero Transfer)
  • 🌊 Output waveform: Pure Sine Wave (THD < 2%)
  • 📊 Power factor: 0.9 – 1.0 (Unity PF)
  • 🌐 Communication: SNMP Card / Modbus / USB
SELECT CAPACITY TIER

Four power tiers, zero transfer time

Continuous pure sine wave protection scaled for mission-critical IT, healthcare, and industrial workloads.

1kVA
Best fit Critical Workstations & Edge Racks
BUILT IN

Zero-compromise mission-critical power

True Zero Transfer Time (0ms)

Continuous AC-DC-AC conversion guarantees zero switching interruption during power loss, safeguarding sensitive IT servers.

Unity Power Factor (PF = 1.0)

Delivers maximum active power capacity (kVA = kW), allowing you to power more high-density server racks per footprint.

Automatic Static Bypass

Instantly shifts the load to utility bypass during severe overloads or internal faults, keeping critical systems powered.

SNMP & Network Management

Remote monitoring via web browser or NMS with automated shutdown triggers for Windows, Linux, and VMware hosts.

External Battery Expansion

Connect daisy-chained external battery packs (EBP) to scale backup runtimes from minutes to multiple hours on demand.

Generator Friendly Input

Wide input frequency and voltage tolerance filters out dirty engine generator power for stable operational output.

SPEC SHEET

Technical specifications

Parameter Specification
Power Rating Range1kVA / 3kVA / 6kVA / 10kVA
Output Power Factor1.0 (Unity)
Input Voltage Range110V – 300V AC (wide range)
Output Voltage Regulation220V / 230V / 240V AC ±1%
Transfer Time0 ms (True Double-Conversion)
Overload Capacity105%–125% for 10 min; 125%–150% for 1 min
EfficiencyUp to 94% Online Mode / 98% ECO Mode
Bypass TypeAutomatic Static Bypass & Manual Maintenance Bypass
External Battery ExpansionSupported via EBP Daisy-Chain Connectors
Communication ProtocolsSNMP / Modbus RS485 / USB / EPO Slot
Operating Temperature0°C to 40°C
CertificationsCE, TUV, IEC/EN 62040-1, IEC/EN 62040-2

* Extended runtime configurations require external battery pack (EBP) modules.

WHERE IT FITS

Zero-transfer protection for zero-downtime environments

1–3kVA

Enterprise IT Racks

Clean, isolated AC power for mission-critical mission servers and core network switches.

3–6kVA

Medical Equipment

Zero-transfer backup power for diagnostic imaging, lab devices, and patient monitors.

6–10kVA

Industrial Automation

Shield PLCs, robotics controllers, and SCADA systems from utility brownouts.

10kVA+

Banking & Data Hubs

Continuous power isolation for transaction processing and server rooms.

Need zero-transfer power isolation for your critical equipment?

Share your IT server rack specs or medical equipment details for a custom double-conversion solution.

Scroll to Top